BQQPM - PS-670 RECHARGEABLE BATTERIES

  • MSDS: BQQPM
  • Manufacturer: POWER SONIC CORP
  • Product Name: PS-670 RECHARGEABLE BATTERIES
  • National Stock Number: 6140-01-225-5935
Product Identification

Product ID:PS-670 RECHARGEABLE BATTERIES
MSDS Date:01/14/1990
FSC:6140
NIIN:01-225-5935
MSDS Number: BQQPM

Responsible Party
POWER-SONIC CORP
3106 SPRING ST
REDWOOD CITY, CA 94063-3929
US

Emergency Phone: 415-364-5001

Info Phone: 415-364-5001

Cage: 56309

Contractor
POWER-SONIC CORP
5242 REDWOOD CITY, CA 94063-3929 US

Telephone: 650-364-5001

Cage: 56309

Ingredients

SULFURIC ACID (SARA III)

CAS: 7664-93-9

RTECS: WS5600000

Fraction By Weight: 17%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3; 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


LEAD (SARA III)

CAS: 7439-92-1

RTECS: OF7525000

Fraction By Weight: 60%

OSHA PEL 0.05 MG/M3;1910.1025

ACGIH TLV: 0.15 MG/M3;DUST 9293

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


LEAD PEROXIDE

CAS: 1309-60-0

RTECS: OG0700000

Fraction By Weight: 20%

Hazards

LD50 LC50 Mixture:ORAL LD50 (RAT)=2140MG/KG(H2SO4)
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:EXPOSURE OCCURS ONLY IF BATTERY CASING
IS BROKEN. ACUTE:INHAL:NASAL AND RESPIRATORY IRRITATION FROM SULFUR
OXIDE FUMES.EYES:BURNS,TISSUE
DAMAGE.SKIN:BURNS,IRRITATION.INGEST:STOMACH IRRITATION.
Explanation of Carcinogenicity:LEAD AND LEAD COMPOUNDS ARE LISTED BY
IARC AS POSSIBLY CARCINOGENIC TO HUMANS.
Effects of Overexposure:EYE/SKIN:IRRITATION, BURNS, PAIN.
INHALATION:COUGHING, CHOKING.
Medical Cond Aggravated by Exposure:PERSONS WITH PRE-EXISTING
RESPIRATORY AILMENTS MAY BE AT INCREASED RISK FROM EXPOSURE TO
SULFUR OXIDE FUMES.

First Aid

First Aid:INHALATION:REMOVE TO FRESH AIR. EYE CONTACT: FLUSH WITH WATER
FOR 15 MINUTES. GET MEDICAL HELP. SKIN CONTACT:WASH WITH SOAP AND
WATER. GET MED ATTENTION IF SYMPTOMS PERSIST. INGESTION:DO NOT
INDUCE VO MITING, DRINK 2-4 GLASSES OF WATER. GETMEDICAL HELP
IMMEDIATELY.

Fire Fighting

Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE.
Fire Fighting Procedures:THE NON-CONDUCTIVE POLYSTYRENE CASING IS
NON-FLAMMABLE PER UL94 RATING VE-0 OR VE-1.USE SELF-CONTAINED
BREATHING APPARATUS AND FULL PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:COMBUSTION OR HEAT OF FIRE MAY PRODUCE
HAZARDOUS DECOMPOSITION PRODUCTS AND VAPORS.OVERCHARGING MAY RESULT
IN EXPLOSION,PARTICULARLY IN GAS TIGHT ENCLOSURES.

Accidental Release

Spill Release Procedures:THE ELECTROLYTE IS IMMOBILIZED AND COMPLETELY
SECURED WITHIN THE BATTERY CASE. WEAR GLOVES, SECURE BATTERY IN
POLYETHYLENE BAGS.
Neutralizing Agent:10% BAKING SODA SOLUTION.

Handling

Handling and Storage Precautions:STORE IN A COOL, DRY PLACE.
Other Precautions:NONE

Exposure Controls

Protective Gloves:PVC WHEN HANDLING RUPTURED BATTERY.
Eye Protection:SAFETY GOGGLES
Work Hygienic Practices:AVOID CONTACT WITH BATTERY CONTENTS.
Supplemental Safety and Health
NONE

Chemical Properties

HCC:N1
Appearance and Odor:RECTANGULAR/SQUARE IN SHAPE;ORANGE;NO ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STONG OXIDIZING AGENTS,MATERIELS WHICH WILL ATTACK THE CASING.
Stability Condition to Avoid:OPEN FLAMES, OVERCHARGING,SHORTING.
Hazardous Decomposition Products:SULFURIC ACID WILL PRODUCE TOXIC
OXIDES OF SULFUR.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:DO NOT INCINERATE. SEND FOR RECLAMATION TO
MANUFACTURER OR DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their